Model | Docs | Frequency (MHz) | Power (Watts CW) | Connector Type | Interface |
---|---|---|---|---|---|
WPM11356 | 1.5 - 32 | 500 | N-Female | Coaxial | |
WPM11071 | 1.5 - 32 | 2500 | 7/16-Female | Coaxial | |
WPM11357 | 1.5 - 32 | 5000 | 7/16-Female | Coaxial | |
WPM11199 | 1.5 - 32 | 10000 | 1 5/8" EIA | Coaxial | |
WPM11073 | 1.5 - 32 | 25000 | 1 5/8" EIA | Coaxial | |
WPM11514 | 1.5 - 32 | 25000 | 3 1/8" EIA | Coaxial | |
WPM11355 | 1.5 - 32 | 50000 | 3 1/8" EIA | Coaxial | |
WPM11358 | 1.5 - 100 | 500 | N-Female | Coaxial | |
WPM11320 | 1.5 - 100 | 1000 | N-Female | Coaxial | |
WPM11317 | 1.5 - 100 | 2500 | 7/16-Female | Coaxial | |
WPM11322 | 1.5 - 100 | 10000 | 1 5/8" EIA | Coaxial | |
WPM11380 | 1.5 - 100 | 10000 | LC-Female | Coaxial | |
WPM11714 | 2 - 45 | 25000 | 3 1/8" EIA | Coaxial | |
WPM11323 | 2 - 50 | 200 | N-Female | Coaxial | |
WPM11324 | 2 - 50 | 1000 | N-Female | Coaxial | |
WPM11316 | 2 - 50 | 2500 | 7/16-Female | Coaxial | |
WPM11373 | 2 - 50 | 5000 | LC-Female | Coaxial | |
WPM11326 | 2 - 50 | 10000 | 1 5/8" EIA | Coaxial | |
WPM11383 | 2 - 50 | 10000 | 7/16-Female | Coaxial | |
WPM11386 | 2 - 50 | 25000 | 1 5/8" EIA | Coaxial | |
WPM11681 | 2 - 128 | 10000 | QC Block | Coaxial | |
WPM11490 | 10 - 127 | 20000 | LC-Female | Coaxial | |
WPM11363 | 10 - 200 | 500 | N-Female | Coaxial | |
WPM11332 | 10 - 200 | 10000 | 1 5/8" EIA | Coaxial | |
WPM11416 | 10 - 300 | 10000 | LC-Female | Coaxial | |
WPM11364 | 10 - 500 | 500 | N-Female | Coaxial | |
WPM11334 | 10 - 500 | 1000 | N-Female | Coaxial | |
WPM10800 | 20 - 200 | 10000 | LC-Female | Coaxial | |
WPM11343 | 20 - 520 | 1000 | N-Female | Coaxial | |
WPM11376 | 20 - 520 | 2500 | 7/16-Female | Coaxial | |
WPM11335 | 20 - 1000 | 200 | N-Female | Coaxial | |
WPM11367 | 20 - 1000 | 500 | N-Female | Coaxial | |
WPM11340 | 20 - 1000 | 1000 | N-Female | Coaxial | |
WPM11678 | 50 - 500 | 100 | N-Female | Coaxial | |
WPM11368 | 50 - 500 | 500 | N-Female | Coaxial | |
WPM11346 | 80 - 1000 | 200 | N-Female | Coaxial | |
WPM11369 | 80 - 1000 | 500 | N-Female | Coaxial | |
WPM11235 | 80 - 1000 | 1000 | N-Female | Coaxial | |
WPM11072 | 80 - 1000 | 2000 | 7/16-Female | Coaxial | |
WPM11101 | 80 - 1000 | 2500 | 7/16-Female | Coaxial | |
WPM11350 | 100 - 500 | 200 | N-Female | Coaxial | |
WPM11351 | 100 - 500 | 1000 | N-Female | Coaxial | |
WPM11379 | 100 - 500 | 2500 | 7/16-Female | Coaxial | |
WPM11188 | 380 - 400 | 1000 | N-Female | Coaxial | |
WPM11510 | 500 - 2500 | 100 | N-Female | Coaxial | |
WPM11505 | 800 - 2500 | 1500 | 7/16-Female | Coaxial | |
WPM11667 | 900 - 930 | 5000 | 1 5/8" EIA | Coaxial | |
WPM11659 | 1000 - 2000 | 2000 | 7/16-Female | Coaxial | |
WPM11654 | 2400 - 2500 | 5000 | TBR | Waveguide |
Optimal Accuracy
40 dB Dynamic Range
No On-Site Calibration
CAPABILITIES
(Figure 1,2)
Accuracy
Multi-Octave Solution within ± 5% (± 2% typical) of Customer Lab Standard, Across a Full 40 dB Dynamic Range.
Calibration.
No On-Site Calibration Required.
Set Alarm Threshold of Forward Power, Reverse Power, Load VSWR & Temperature.
(Figure 6)
Networkable and SNMP Programmable.
Full VSWR Monitoring/Alarm Capability.
(Figure 1,2)
Full Temperature Monitoring/Alarm Capability.
(Figure 1,2)
Six General Purpose Inputs/Relays with multiple uses.
(Figure 8)
Powered by AC Power or Passive Power Over Ethernet (PPOE).
Remote Interface
through TCP-IP (with SNMP and Browser Interface via LAN), Passive Power over Ethernet, and RS485 Form Addressable Serial Network.
User ID and Password Protection
provides secure monitoring.Figure 1
Figure 2
Programming Capabilities.
Figure 3
Figure 4
Administrative Controls.
Figure 5
Figure 6
Remote I/O
allows access to several important parameter setings.
RELAY 1
can be programmed as an interlock closure or alarm closure. When set to INTERLOCK, the relay will remain closed as long as the Reflected Power is less than the programmed threshold and the conditions of the enabled interlock group(s) is satisfied.
RELAY 2
can be programmed as a second Interlock. Interlock options include an ALARM RELAY, an RF PRESENT CLOSURE, and an RF PRESENCE THRESHOLD. The RF PRESENCE THRESHOLD can be programmed to engage when RF is below a programmed threshold. This seting is a valuable tool for RF safety plans, allowing remote or local indication of RF Presence.
Figure 7
Figure 8
General Purpose Inputs
with multiple uses. (Figure 8)
Accessories:
Werlatone Multi-Channel Display Monitors are designed to interface up to eight Digital Power Meters and are capable of monitoring RF antenna and amplifier systems. Our Multi-Channel Displays will monitor Forward and Reflected Power, as well as Load VSWR, and Temperature.
Designed to distribute transmitter interlock control of up to eight transmitters, our Displays are web-enabled for remote display of all parameters and remote control of fault reset.